Telecom Shelter & Cell Site Cooling

Closed-loop wall-mount and cabinet air conditioners for telecom shelters, walk-in cabinets and outdoor radio enclosures across the Front Range.

Dantherm PrecisionAir 14000 mid-mount 48 VDC shelter air conditioner
Dantherm PrecisionAir 14000 mid-mount 48 VDC shelter air conditioner
Dantherm PrecisionAir air conditioners mounted on outdoor power and battery enclosures

Keep radios, rectifiers and batteries in range

Telecom equipment produces heat around the clock, and an unmanned site has no one on hand when a cooling unit fails. A shelter that runs hot shortens battery life and puts rectifiers and radios at risk of shutting down.

Dantherm designs PrecisionAir specifically for telecom buildings and cabinets. BBCOND installs these units on new shelters, replaces aging wall-mount units on existing sites and adds cooling to outdoor cabinets that have outgrown their fans or heat exchangers. Units are available in 48 VDC, so cooling can run from the same DC plant as the radios.

Call 303-219-1000, email sales@bbcond.com or request a quote.

Telecom sites we cool

  • Cell sites and towers: outdoor radio and power cabinets at the base of the tower
  • Walk-in cabinets (WICs) and huts: small prefab shelters for carrier and fiber equipment
  • Fiber huts and regenerator sites: unmanned network nodes along fiber routes
  • DAS and small cell head-ends: equipment rooms serving in-building and campus wireless
  • Public safety radio sites: two-way radio and dispatch repeater shelters
  • Broadcast transmitter buildings: transmitter and STL equipment enclosures
Dantherm PrecisionAir 14000 mid-mount 48 VDC shelter air conditioner
Dantherm PrecisionAir enclosure air conditioner range and key features

Why Dantherm PrecisionAir

  • Closed-loop cooling: outside air never mixes with enclosure air, keeping dust, moisture and smoke out
  • Rated -40°F to 131°F: built-in heaters (500–2,000 W) for Colorado winters, full capacity in summer heat
  • NEMA 3R construction: galvanized steel standard, stainless steel optional, all-aluminum microchannel coil
  • Efficient, quiet operation: high-static BCI fans, rated by Dantherm at 40–60% less energy; 60–65 dB
  • Remote monitoring: optional ACG7 controller with Ethernet, SNMP v2 or Modbus and a web interface
  • Listed and tested: UL or ETL listings by model; manufactured under ISO 9001

Sizes and power options

  • PrecisionAir 2000: about 2,200–2,500 BTU/h, 115 or 230 VAC
  • PrecisionAir 4000 / 6000: about 4,000–6,000 BTU/h, 115, 230 or 460 VAC three-phase, or 48 VDC
  • PrecisionAir 10000 / 12000 / 14000: about 10,000–14,000 BTU/h; 10000 and 12000 in 208/230 VAC or 48 VDC, 14000 and 14000 mid-mount in 48 VDC
  • PrecisionAir 20000: about 20,000 BTU/h, 208/230 VAC
  • PrecisionAir 24000 / 28000: about 24,000–28,000 BTU/h; 24000 in 208/230 VAC or 48 VDC, 28000 in 48 VDC

Options include an Ethernet controller, stainless steel housing and beige, white or custom finishes. BBCOND sizes each unit from your equipment heat load and site conditions.

Dantherm PrecisionAir 2000 compact electrical cabinet air conditioner
Dantherm PrecisionAir air conditioners mounted on outdoor power and battery enclosures

Serving sites within an hour of Denver

Front Range sites see summer highs in the 90s and winter nights well below zero, often in the same year at the same site. PrecisionAir units are rated to operate from -40°F to 131°F and include an internal heater, so one unit handles both extremes. We install from Denver and Aurora out to mountain sites around Evergreen and the foothills, and north to Boulder and Longmont.

See all enclosure and shelter cooling applications, or related pages: Remote Server Station Cooling in Colorado, Battery Energy Storage (BESS) Cooling in Colorado, Substation & Control House HVAC in Colorado.

Frequently asked questions

  • Can a PrecisionAir unit run on -48 VDC power?

    Several sizes are built for 48 VDC (+20%/-15%), including 4,000, 6,000, 10,000, 12,000, 14,000, 24,000 and 28,000 BTU/h models.

  • Can I set up lead/lag redundancy?

    Shelters are often fitted with two units for redundancy. We size and configure the units so one can carry the load if the other is down.

  • Can I monitor the unit from our NOC?

    Yes. The optional ACG7 controller provides Ethernet with SNMP v2 or Modbus and a web interface for remote alarms and set points.

Contact Us

Tell us about your project and we’ll get back to you.

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.