Turn a steel box into a protected equipment room
Shipping containers are a fast, secure way to house generators, controls, servers and batteries. Uninsulated steel walls also make them heat traps in summer and cold boxes in winter, which is hard on electronics.
PrecisionAir units mount directly to the container wall, cool the interior with a closed air loop and include a heater for cold weather. BBCOND handles unit selection, wall cutouts, mounting, electrical connection and start-up for container fabricators, integrators and end users.
Call 303-219-1000, email sales@bbcond.com or request a quote.
Container applications
- Containerized data centers: server racks and network gear in ISO containers
- Battery and inverter containers: energy storage and power conversion
- Control and pump containers: controls for water, oil and gas and industrial process
- Generator control containers: switchgear and controls packaged with generators
- Telecom equipment containers: temporary and permanent communications sites
- Lab and test containers: instrumentation and test equipment on site


Why Dantherm PrecisionAir
- Closed-loop cooling: outside air never mixes with enclosure air, keeping dust, moisture and smoke out
- Rated -40°F to 131°F: built-in heaters (500–2,000 W) for Colorado winters, full capacity in summer heat
- NEMA 3R construction: galvanized steel standard, stainless steel optional, all-aluminum microchannel coil
- Efficient, quiet operation: high-static BCI fans, rated by Dantherm at 40–60% less energy; 60–65 dB
- Remote monitoring: optional ACG7 controller with Ethernet, SNMP v2 or Modbus and a web interface
- Listed and tested: UL or ETL listings by model; manufactured under ISO 9001
Sizes and power options
- PrecisionAir 2000: about 2,200–2,500 BTU/h, 115 or 230 VAC
- PrecisionAir 4000 / 6000: about 4,000–6,000 BTU/h, 115, 230 or 460 VAC three-phase, or 48 VDC
- PrecisionAir 10000 / 12000 / 14000: about 10,000–14,000 BTU/h; 10000 and 12000 in 208/230 VAC or 48 VDC, 14000 and 14000 mid-mount in 48 VDC
- PrecisionAir 20000: about 20,000 BTU/h, 208/230 VAC
- PrecisionAir 24000 / 28000: about 24,000–28,000 BTU/h; 24000 in 208/230 VAC or 48 VDC, 28000 in 48 VDC
Options include an Ethernet controller, stainless steel housing and beige, white or custom finishes. BBCOND sizes each unit from your equipment heat load and site conditions.


Serving sites within an hour of Denver
We work with fabricators and owners within about an hour of Denver, including industrial areas in Commerce City, Denver, Henderson, Brighton and Aurora. We can install at the fabricator’s yard or at the final site.
See all enclosure and shelter cooling applications, or related pages: Electrical Cabinet Air Conditioner in Denver, Lift Station & SCADA Panel Cooling in Colorado, Traffic Signal & ITS Cabinet Cooling in Denver.
Frequently asked questions
-
How big a unit does a 20 or 40 foot container need?
It depends on the equipment heat load, insulation and sun exposure. We calculate the load and match it to a unit between 2,000 and 28,000 BTU/h.
-
Can you cut the container wall for the unit?
Yes. We lay out the cutouts from the manufacturer’s dimensional drawings and seal the installation.
-
Is a heater included?
PrecisionAir units include heaters from 500 to 2,000 watts depending on the model.